Dielectric characteristics of insulation system of large rotating machines can be affected by operational and environmental conditions. Humidity, temperature and contamination affect dielectric parameters such as insulation resistance, polarization index and dissipation factor in certain degrees. In order to investigate the effect of humidity on characteristics of modern insulation systems, some bars with different insulation materials or different manufacturing processes were subjected to high humidity for a certain period and its effect on time and frequency domain dielectric responses were studied. Also to study the effect of water contamination of the insulation system, some bars were partially immersed in water and the variation of parameters such as insulation resistance, polarization index, loss factor, etc. were investigated. AC and DC hipot tests were conducted to verify the degree of effect of humidity/water absorption on dielectric strength of the insulation materials.
机译:大型旋转机器的绝缘系统的介电特性可能受到操作和环境条件的影响。湿度,温度和污染影响介电参数,例如绝缘电阻,偏振指数和某些程度的耗散因子。为了探讨湿度对现代绝缘系统特性的影响,对具有不同绝缘材料或不同制造过程的一些杆进行了一段时间的高湿度,并研究了对时间和频域介电反应的影响。另外,研究了保温系统的水污染的影响,研究了一些条浸入水中,并研究了绝缘电阻,极化指数,损耗因子等的参数的变化。进行AC和DC HIPOT测试以验证湿度/吸水性对绝缘材料的介电强度的影响程度。