This paper presents results from experimental investigations performed in order to characterize and compare electrical tree formation in extruded syndiotactic polypropylene (s-PP) and cross-linked polyethylene (XLPE) cable insulation. All tests were performed using molded needle-plate samples with an insulation distance of 1.05 mm. Initiation and formation of electrical trees from the needle tips were studied using partial discharge measurements and optical microscopy video techniques. The tree growth was characterized by measuring length and width of the trees, the time needed for the first branch to reach the opposite ground electrode and time to electric breakdown. The effect of different AC voltages, with magnitudes up to 12 kV and frequencies in the range of 50 – 1000 Hz, were examined.
机译:本文提出了在挤出的长立 - 立丙烯(S-PP)中的表征和比较电气树形成和交联聚乙烯(XLPE)电缆绝缘中的实验研究的结果。使用模压针板样品进行所有测试,其绝缘距离为1.05mm。使用局部放电测量和光学显微镜视频技术研究了从针尖开始和形成电气树的启动和形成。树长的特征在于测量树的长度和宽度,第一分支到达相反接地电极的时间和电击的时间。检查不同AC电压的效果,大于12 kV的大于12kV,频率在50-1000Hz的范围内。