In order to solve the problem of pollution flashover in the strain insulator-strings on transmission line in China, a large number of insulators with RTV silicone coatings are used for the transmission line. This paper summarize the experience of using RTV coatings for disc insulators on transmission lines in China, the main existing problems of RTV operation, such as poor adhesion, hydrophobicity decline, powder and product pollution, are pointed out. Some problems are related to the way of spraying on the tower in jobsite, because the detection methods are not effective and the quality of spraying could not be controlled, at the same time. So, the pre-coated RTV insulators have been widely used in UHV projects. Experimental studies show that pre-coated RTV insulators have a clear technological advantage in the quality of appearance, thickness uniformity, adhesion and so on. But it also founds that the combination of disc insulator with RTV coating leads to the sharp decline of steep-front impulse breakdown performance of insulator. Most of breakdown happened at the negative voltage polarity moment. Under the negative polarity voltage, the discharge channel tends to select the RTV coatings surface.
机译:为了解决中国传输线上应变绝缘子串的污染闪络问题,具有RTV硅胶涂层的大量绝缘体用于传输线。本文总结了使用RTV涂层在中国传输线上的RTV涂层的经验,rtv操作的主要存在问题,如差的附着力,疏水性下降,粉末和产品污染。有些问题与在博物馆中喷涂塔的方式有关,因为检测方法无效,同时无法控制喷涂质量。因此,预涂层的RTV绝缘体已广泛用于UHV项目。实验研究表明,预涂层的RTV绝缘体具有清晰的技术优势,在外观的质量,厚度均匀性,粘附等方面具有明显的技术优势。但它还发现,圆盘绝缘体与RTV涂层的组合导致绝缘体陡峭的脉冲击穿性能的急剧下降。大多数故障发生在负电压极性时刻。在负极电压下,放电通道倾向于选择RTV涂层表面。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号