首页> 外文会议>International Conference on High Voltage Engineering and Application >Simulation study on the technology of interphase interference and spatial interference in metal oxide arrester (MOA) on-line test
【24h】

Simulation study on the technology of interphase interference and spatial interference in metal oxide arrester (MOA) on-line test

机译:金属氧化物避雷器(MOA)在线试验中的间干扰和空间干扰技术的仿真研究

获取原文

摘要

Due to the intensive arrangement of the transformer substation equipment, there is coupling capacitance between conductors, which leads to serious interphase interference and spatial interference in MOA on-line testing. This interference was able to make the leakage current of three-phase arrester in great difference, especially the resistive current, and subsequently, the deterioration situation of arrester valve plate cannot be accurately estimated. In this paper, a simulation model was established based on the interphase interference and spatial interference situation in MOA on-line testing, which aims to analyze the interference mechanism and then to eliminate the interference. Ultimately, the leakage current and phase after filtering out interference can be got by means of interference current calculation with coupling capacitance.
机译:由于变电站设备的密集布置,导体之间存在耦合电容,导致MOA在线测试中的严重间干扰和空间干扰。这种干扰能够使三相避雷器的漏电流在很大差异,尤其是电阻电流,随后,不能精确地估计避雷器阀板的劣化情况。在本文中,基于MoA在线测试中的间干扰和空间干扰情况来建立仿真模型,旨在分析干扰机制,然后消除干扰。最终,通过耦合电容的干涉电流计算,可以通过干涉电流计算来获得滤波后的漏电流和相位。

著录项