Due to the intensive arrangement of the transformer substation equipment, there is coupling capacitance between conductors, which leads to serious interphase interference and spatial interference in MOA on-line testing. This interference was able to make the leakage current of three-phase arrester in great difference, especially the resistive current, and subsequently, the deterioration situation of arrester valve plate cannot be accurately estimated. In this paper, a simulation model was established based on the interphase interference and spatial interference situation in MOA on-line testing, which aims to analyze the interference mechanism and then to eliminate the interference. Ultimately, the leakage current and phase after filtering out interference can be got by means of interference current calculation with coupling capacitance.
机译:由于变电站设备的密集布置,导体之间存在耦合电容,在MOA在线测试中会导致严重的相间干扰和空间干扰。这种干扰使三相避雷器的泄漏电流,特别是电阻电流有很大的差异,因此,不能准确地估算出避雷器阀板的劣化情况。本文基于MOA在线测试中的相间干扰和空间干扰情况,建立了仿真模型,旨在分析干扰机理,消除干扰。最终,通过使用耦合电容计算干扰电流,可以得出滤除干扰后的漏电流和相位。