首页> 外文会议>Power Plant Air pollutant Control "MEGA" Symposium >Demonstration of the BW PGG/GEA Niro SDA Peak Control System
【24h】

Demonstration of the BW PGG/GEA Niro SDA Peak Control System

机译:B&W PGG / GEA Niro SDA峰值控制系统的示范

获取原文

摘要

Performance of the well-proven spray dryer absorption (SDA) process for the control of acid gas and hazardous air pollutant (HAP) emissions in coal-fired boiler applications can be enhanced by the addition of dry hydrated lime to the process. This peak control process modification has been used by GEA Niro in European energy-from-waste applications. SDA performance with dry lime addition for enhanced emissions control on cold boiler startup was demonstrated at the nominal 110 MW Wygen 3 - Unit #5 in Wyoming. This approach was also used to demonstrate the potential to increase sulfur dioxide (SO_2) removal to address the impact of increasing fuel sulfur in combination with a pending reduction in the regulated emission level for an installation in the Czech Republic. System responsiveness, SO_2 emissions, and impacts on auxiliary systems from both sites are addressed in this paper.
机译:通过向该过程中加入干湿性石灰,可以提高燃煤锅炉应用中酸性气体和危险空气污染物(HAP)排放的经过熟练的喷雾干燥器吸收(SDA)的性能。 GEA Niro在欧洲能源 - 从废物应用中使用了该峰值控制过程修改。在怀俄明州的标称110 MW Wygen 3 - 单元#5中展示了对冷锅炉启动的增强型排放控制的干式灰化的SDA性能。这种方法还用于证明增加二氧化硫(SO_2)去除以解决增加燃料硫的影响与捷克共和国安装的额外排放水平的待定减少的待遇。在本文中解决了系统响应性,SO_2排放和对来自两个站点的辅助系统的影响。