首页> 外文会议>International Conference on Mechatronic Systems and Materials >The Influence of the Angular Position of the Laser Triangular Head on the Readings of the Measurement System
【24h】

The Influence of the Angular Position of the Laser Triangular Head on the Readings of the Measurement System

机译:激光三角形头角位置对测量系统读数的影响

获取原文

摘要

The article presents the methodology, test stand and results of noncontact tests conducted using a laser sensor-equipped system for measuring displacement. The tests were carried out in an attempt to determine the sensitivity of the measurement system to the angular position of the sensor against the surface onto which the laser spot was projected. The scope of investigations constitutes a crucial problem dealing with the determination of tolerance of assembling a laser head in the measurement system for a laser penetrometer used for examining substance consistence. The tests were executed in the measurement range between 5 and 50 mm taking into account 5 angular positions of the laser sensor. The readings of the laser head were referred to the value of displacements adjusted with the use of a micrometric head. In the case of the tested system, the dispersion of measurement deviations was estimated as a function of the measured distance.
机译:本文介绍了使用配备激光传感器的系统进行用于测量位移的非接触式测试的方法,测试支架和结果。 进行测试,以试图确定测量系统对传感器的角度位置抵靠投影激光光斑的表面的灵敏度。 调查范围构成了处理在用于检查物质的激光渗滤体中在测量系统中组装激光头的耐受性的关键问题。 考虑到激光传感器的5个角位置,在5到50mm的测量范围内执行测试。 激光头的读数被称为使用微米头调节的位移值。 在测试系统的情况下,测量偏差的分散估计为测量距离的函数。