Transformers are key elements in power generation, transmission and distribution systems. Transformers under PWM supply are essential elements in industrial applications such as active power line conditioning, electrified railway power systems, PWM DC-DC power converters. Assessing the performance of transformers under PWM supplies is relevant to these applications. In this paper, the variation of iron losses with switching frequency in the range of 1 kHz - 3 kHz in a three-phase, three-limb transformer core under no-load conditions was measured. Classical eddy-current losses were calculated for various values of modulation index and magnetization conditions (frequency 50 Hz, 100 Hz; induction 1.3 T, 1.5 T). Results showed a reduction of the eddy-current component of loss by up to 40% at low frequency of magnetization and low modulation index with high switching frequency.
机译:变压器是发电,传输和分配系统中的关键要素。 PWM供应下的变压器是工业应用中的必要元素,如有源电力线调节,电气化铁路电源系统,PWM DC-DC电源转换器。根据PWM耗材评估变压器的性能与这些应用有关。在本文中,测量了在空载条件下,在三相中,在1kHz - 3kHz的范围内具有开关频率的铁损的变化。计算古典涡流损耗,用于各种调制指数和磁化条件(频率50Hz,100Hz;诱导1.3 T,1.5 T)。结果表明,在低频的磁化和具有高开关频率的低调制指数下,减少了高达40%的损耗损耗。