241-AY-102 Leak Detection Pit Drain Line Inspection

机译:241-AY-102泄漏检测坑排水线检查

获取原文
获取外文期刊封面目录资料

摘要

On August 1, 2012 a routine visual inspection showed the presence of unexpected material on the floor of the secondary liner in Tank 241-AY-102 (AY-102). In October 2012, it was determined that waste had leaked into the annulus of AY-102. As a result, an extensive review of Tank AY-102 was conducted quickly triggering increased inspection and monitoring of the tank;;however, the precise cause and location of the leak could not be determined. At the same time the Tank AY-102 leak detection pit (LDP) was accumulating water through the drain system external to the secondary tank liner. Liquid collecting in the LDP is suspected to be from water intrusion and collects at a rate such that the LDP must be pumped routinely. Following a routine pumping event, elevated radiation dose rates were noted on the transfer hose and surface contamination readings were found on the transfer pump when it was removed from the Tank AY-102 LDP. These two field readings suggested that tank waste from a secondary liner breach could be leaking into the LDP.
机译:2012年8月1日,常规视觉检查显示罐241-AY-102(AY-102)的次级衬垫地板上存在意外材料。 2012年10月,确定废物泄漏到AY-102的环上。结果,对坦克AY-102进行了广泛的回顾,迅速触发了对坦克的增加的检查和监测;但是,无法确定泄漏的精确原因和位置。同时,坦克AY-102泄漏检测坑(LDP)累积水通过次罐衬里外部的排水系统。 LDP中的液体收集是从水侵入的速度收集并以速度收集,使得LDP必须常规泵送。在常规泵送事件之后,在转移软管上注意到升高的辐射剂量率,并且在从罐AY-102 LDP中除去时,在转移泵上发现表面污染读数。这两个场景读数表明,来自次级衬垫违规的坦克废物可能会泄漏到LDP中。