Low-voltage-networks operate with a nominal voltage charged with a tolerance range. Consumer’s installations (CI) are feeded with different supply-voltages which depend on the location of the CI within the LV-grid and the load flow. At the feeding point of the CI no additional regulating device is foreseen. Local-Energy-Controllers can decrease the supply-voltage and influence the energy consumption of the CI. This paper shows when LECs operate properly and which preconditions have to be fulfilled for the energy-saving. Different consumer categories and the calculation algorithm for the amount of the energy saving will be introduced. At the end the algorithm will be compared with results of real LEC-installations. The properly engineered operation of an LEC saves energy, energy costs and reduce CO2, without affecting the power-quality negatively.
机译:低压网络以具有公差范围充电的标称电压操作。消费者的装置(CI)用不同的电源电压馈送,这取决于LV-Grid内CI的位置和负载流量。在CI的进料点处,未预见额外的调节装置。局部能量控制器可以降低电源电压并影响CI的能量消耗。本文展示了LEC适当运行,并且必须满足哪些先决条件以节省节能。将引入不同的消费类别和节能量的计算算法。最后,将与实际LEC安装结果进行比较。 LEC的适当工程操作节省了能量,能源成本和减少CO 2 ,而不会产生负面质量。