Examples of International flicker requirements in high voltage networks and real world measurements

机译:高压网络和现实世界测量中的国际闪烁要求的示例

获取原文

摘要

Comparing flicker planning levels and flicker requirements given by utility companies world wide, it can be found that there are great differences in these planning levels and thus in requirements to companies which have installed flicker generating equipment such as arc furnaces, welders etc. Taking into account that the flicker immunity of equipment, connected to LV systems and the flicker sensitivity of inhabitants of residential customers are more or less equal in a globalized world, there is no real reason that in certain areas, resp. in certain standards the planning levels are extremely low. In this case such planning levels can give remarkable competitive disadvantages for the industry, if companies have to reduce e.g. the furnace power or have to install expensive additional compensation equipment, e.g. statcom systems. The aim of this paper is, to compare international resp. national planning levels for flicker in high voltage networks and the flicker requirements which must be fulfilled by customers running flicker generating equipment like arc furnaces. It can be shown that in many cases the real flicker values in high voltage networks, which are supplying towns with industrial areas, are much higher than the planning levels without creating complaints by private consumers. This shall be proved using results of "real world" flicker measurements. The real world examples prove that flicker values in high voltage systems can be much higher than the usual planning levels without causing complaints by residential customers which are supplied via medium voltage and low voltage from these systems. This fact is already taken into account by some utilities but unfortunately it has not yet found access to the national and international standards or recommendations. On this field there is still much work to do.
机译:比较闪烁规划水平和公用事业公司世界范围内的闪烁要求,可以发现这些规划水平存在很大差异,从而对已经考虑的闪烁发电设备(如弧炉等)的公司的要求设备的闪烁免疫,与LV系统相关的,住宅客户的居民的闪烁敏感度在全球化的世界中,没有真正的原因,在某些领域,RESP。在某些标准中,规划水平极低。在这种情况下,如果公司必须减少,则这种规划水平可以为行业提供显着的竞争缺点。炉子电源或必须安装昂贵的附加补偿设备,例如昂贵的额外补偿设备。 Statcom系统。本文的目的是比较国际录音。高压网络中闪烁的国家规划水平及闪烁要求必须由运行闪烁发电设备等电弧炉的客户满足。可以表明,在许多情况下,高电压网络中的真正闪烁值,这些高压网络具有工业区域的城镇,远高于规划水平,而不会产生私人消费者的投诉。这将使用“现实世界”闪烁测量结果证明。真实世界的例子证明了高压系统中的闪烁值可以远高于通常的规划水平,而不会通过中压和来自这些系统的低压提供的住宅客户的投诉。一些公用事业公司已经考虑了这一事实,但遗憾的是尚未确定进入国家和国际标准或建议。在这个领域,还有很多工作要做。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号