首页> 外文会议>International Dairy Housing Conference >Consumptive Water Use of Evaporative Pads
【24h】

Consumptive Water Use of Evaporative Pads

机译:消耗水的蒸发垫的用水

获取原文

摘要

Dairies are using evaporative pads to cool air in tunnel ventilated facilities. However, additional information is needed to ensure adequate water is available to meet the demands of the evaporative pad system. The objective of this study was to determine the water usage of an evaporative pad. Consumptive water usage by evaporative pads was measured during 7 days of a 3-week period at a Kansas (KS) dairy and a 2-day period at a North Dakota (ND) dairy. Water meters were installed between the water hydrants and evaporative pads at each dairy and monitored. Data was recorded every 30 minutes during 5 hrs at the KS site and 15 minutes during 1 to 2.5 hrs at the ND site. Ratio of pad area to cow equaled 0.45 m~2 (4.8 ft~2) and 0.42 m~2 (4.5 ft~2) per cow at the KS and ND sites, respectively. Air velocities through the pads were 0.5 m/s (1.2 mph), 0.9 m/s (2.1 mph), and 1.4 m/s (3.2 mph) at the ND dairy and 1.5 m/s (3.3 mph) at the KS dairy. During the study period in KS, the temperature humidity indexranged from 78 to 86 and water usage varied from 2.6 L/min (0.7 gpm) to 17.6 L/min (4.7 gpm). Average pad efficiency equaled 62%. Water usage averaged 0.2 L/min/m~2 (0.3 gal/hr/ft~2) of pad when airflow rate was 1.5 m/s (3.3 mph) to 1.6 m/s (3.6 mph). Atthe ND dairy, the water usage averaged 0.07 L/min/m~2 (0.1 gal/hr/ft~2), 0.20 L/min/m~2 (0.3 gal/hr/ft2) and 0.26 L/min/m~2 (0.38 gal/hr/ft~2) of pad for the low, medium, and high airflow rates, respectively. The temperature humidity index inside thefreestall building equaled 65, 72.5, and 71 for the low, medium, and high airflow study periods. Pad efficiency averaged 93, 86, and 81% from the low to high airflow rates. Similar to pad efficiencies at the KS site, efficiency increased as the outdoor airtemperaturedecreased.
机译:奶粉正在使用蒸发垫在隧道通风设施中冷却空气。但是,需要额外的信息来确保充足的水可用于满足蒸发垫系统的需求。本研究的目的是确定蒸发垫的用水。在堪萨斯(ks)乳制品的3周期内的7天内测量蒸发垫的消耗水分,并在北达科他州(Nd)乳制品的2天期。水表安装在水消防栓和每个乳制品的蒸发垫之间,并监测。在KS站点的5小时内每30分钟记录每30分钟的数据,在ND站点的1至2.5小时内为15分钟。垫区域与母牛的比例分别在Ks和Nd位点分别等于0.45m〜2(4.8英尺2)和0.42m〜2(4.5英尺2)。通过垫的空气速度为0.5m / s(1.2mph),0.9m / s(2.1mph),ND乳制品的1.4 m / s(3.2英里/小时),Ks乳制品1.5 m / s(3.3英里/小时) 。在KS的研究期间,从78〜86和水的温度湿度降低,水的用法在2.6L / min(0.7gpm)中变化至17.6L / min(4.7gpm)。平均垫效率平均62%。当气流速率为1.5米/秒(3.3mph)至1.6 m / s时,水的使用平均为0.2万/ min / m〜2(0.3 gal / hr / ft〜2)垫。在ND乳制品中,水的使用平均为0.07升/分钟/ m〜2(0.1 gal / Hr / Ft〜2),0.20 L / min / m〜2(0.3 gal / Hr / Ft2)和0.26 L / min / m 〜2(0.38加仑/ Hr / ft〜2)垫的低,介质和高气流速率。 FreeStall建筑内的温度湿度指数平均为65,72.5和71,用于低,中等和高气流研究。垫效率平均为93,86和81%,从低到高气流速率。与KS网站的垫效率类似,效率随着户外空气化的效率而增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号