Both Static and dynamic electric load characteristics have considerable effect on short circuit ratio (SCR) or effective short circuit ratio (ESCR). This paper gives emphasis on the relationship between static/dynamic load characteristics and SCR (ESCR). Different power level with different power factor is considered for the impacts on SCR or ESCR of static load characteristics. Three-phase short-circuit current of induction motors is qualitative analyzed and simulation of the feeding current is carried out for the dynamic process of induction motor in the consideration of dynamic load characteristics. Case studies are carried out on WEPRI-36 system and Hunan power grid. Simulation results with Power System Analysis Software Package (PSASP) illustrates that load should be considered in calculating SCR.
机译:静电和动态电负载特性均对短路比(SCR)或有效的短路比(ESCR)具有相当大的影响。本文重点强调静态/动态负载特性与SCR(ESCR)之间的关系。不同功率因数的不同功率电平被认为是对SCR或静态负载特性的影响的影响。感应电动机的三相短路电流是定性分析的,并且在考虑动态负载特性时,对感应电动机的动态过程进行了进料电流的仿真。案例研究是在Wepri-36系统和湖南电网上进行的。电源系统分析软件包(PSASAs)的仿真结果说明了在计算SCR时应考虑负载。