首页> 外文会议>Intermag Conference >Corrosion-Resistant GMR Head for Over-1TB Tape System
【24h】

Corrosion-Resistant GMR Head for Over-1TB Tape System

机译:用于超过1TB磁带系统的耐腐蚀GMR头

获取原文

摘要

A helical-scan tape system using a conventional GMR head and thin metal-evaporated (ME) tape was developed [1][2]. It was previously reported that a GMR head with a corrosion-resistant spin-valve (SV) exhibited good corrosion resistance against the NaCl solution [3]. In this paper, the corrosion-resistant GMR head is exposed to corrosive gases, the recording characteristics is measured using a helical-scan tape system.
机译:使用常规GMR头和薄金属蒸发(ME)胶带的螺旋扫描胶带系统[1] [2]。先前报道,具有耐腐蚀的旋转阀(SV)的GMR头对NaCl溶液具有良好的耐腐蚀性[3]。在本文中,耐腐蚀的GMR头暴露于腐蚀性气体,使用螺旋扫描磁带系统测量记录特性。

著录项