This study aims at the development of non-contact dry eye diagnosis based on an infrared thermal imager system, which was used to measure the cooling of the ocular surface temperature of normal and dry eye patients. A total of 108 subjects were measured, including 26 normal and 82 dry eye patients. We have observed that the dry eye patients have a fast cooling of the ocular surface temperature than the normal control group. We have developed a simplified algorithm for calculating the temperature decay constant of the ocular surface for discriminating between normal and dry eye. This study shows the diagnostic of dry eye syndrome by the infrared thermal imager system has reached a sensitivity of 79.3%, a specificity of 75%, and the area under the ROC curve 0.841. The infrared thermal imager system has a great potential to be developed for dry eye screening with the advantages of non-contact, fast, and convenient implementation.
机译:本研究旨在基于红外热成像系统的非接触式干眼诊断的发展,用于测量正常和干眼患者的眼表面温度的冷却。测量总共108个受试者,包括26例正常和82例干眼症患者。我们已经观察到干眼患者的眼表面温度快速冷却比正常对照组。我们开发了一种简化的算法,用于计算眼表面的温度衰减常数,以区分正常和干眼。本研究表明,红外热成像仪系统的干眼症综合征诊断达到了79.3%的敏感性,特异性为75%,以及ROC曲线下的面积0.841。红外线热成像仪系统具有较大的潜力,可用于干眼屏筛选,具有不触点,快速,方便的实施的优点。