Smoke Particulate Sensors for OBD and High Precision Measuring

机译:烟雾颗粒传感器,用于OBD和高精度测量

获取原文

摘要

Carbon particles have the capability to be electrically charged. A very high static electrical field attracts particles through Coulomb forces in that they touch statistically the high voltage electrode of a capacitor incorporated into the main exhaust gas flow. By touching the electrode they are charged. Having the same polarity they are repelled and move to the grounded electrode where they are discharged. This procedure produces an electrical current. The RMS value of this amplified signal represents the particle mass. The dependency on the gas flow speed is corrected by a mathematical procedure incorporating the intake parameters of the engine. For high accurate measurements a low constant exhaust gas speed is necessary achieved by a pump sucking the gas through a bypass. To avoid interference from capacitor blade vibrations and gas flow oscillations inside the exhaust silencers a low-pass filter with a cut-off frequency of 2 Hz e.g. is necessary. Another method of measuring smoke particles consists of using the property of carbon conducting electrical current. Between bifilar winded electrodes carbon particles produce electrical resistance bridges and gradually reduce the isolation resistance. This principle is used for measuring the mass of particles in total. By deriving the gradient of the resistance changes the dynamic particle concentration is measured. The bifilar coil consists of resistance material. By simply shortening the ends of the coils the measuring device is also used for burning the particles. The smallest device has the size of a spark plug. The surface of a ceramic heater is sputtered with electrodes having a very small gap in order to optimize the reaction time. This particle summarizing measurement technology is used for monitoring particle traps.
机译:碳颗粒具有电荷的能力。非常高的静电场通过库仑力吸引颗粒,因为它们在统计上触摸结合到主废气流中的电容器的高压电极。通过触摸它们的电极。它们被排斥并移动到它们被排出的接地电极的极性相同。该过程产生电流。该扩增信号的RMS值表示颗粒质量。通过包含发动机的进气参数的数学过程校正对气体流速的依赖性。对于高精度测量,通过旁路吸入气体的泵,可以实现低恒定的废气速度。为了避免从电容器叶片振动的干扰和排气沉默内部的气流振荡,低通滤波器具有2 Hz的截止频率。是必要的。测量烟雾颗粒的另一种方法包括使用碳传导电流的性质。在双丝缠绕电极之间产生电阻桥并逐渐降低隔离电阻。该原理用于测量总量的颗粒质量。通过衍生电阻改变的梯度,测量动态颗粒浓度。双叶片由电阻材料组成。通过简单地缩短线圈的端部,测量装置也用于燃烧颗粒。最小的设备具有火花塞的尺寸。用具有非常小的间隙的电极溅射陶瓷加热器的表面,以优化反应时间。该粒子总结测量技术用于监测粒子陷阱。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号