首页> 外文会议>International Conference on Structural Dynamics >Dynamic assessment of the axial force in the tie-rods of the Milan Cathedral
【24h】

Dynamic assessment of the axial force in the tie-rods of the Milan Cathedral

机译:米兰大教堂拉杆轴向力的动态评估

获取原文

摘要

The Milan Cathedral, constructed over a period of more than 400 years, is one of the few Gothic cathedrals where permanent metallic tie-rods are installed under all naves to support a portion of the lateral thrust exerted by vaults and arches. After the recent failure of one tie-rod, an extensive research program was carried out to characterize the metallic material and to evaluate the axial forces and the tensile stresses of the tie-rods through dynamic testing and system identification. After a description of the methodology adopted in the dynamic assessment of tie-rods in the Milan Cathedral, the paper presents the main results of the investigation, in terms of fundamental frequencies and axial forces in the tie-rods.
机译:米兰大教堂在400多年的时间内构建,是少数哥特式大教堂之一,其中永久金属扎根安装在所有导航下方,以支持拱顶和拱门施加的侧向推力的一部分。在近期一个拉杆失效之后,进行了广泛的研究计划,以表征金属材料,并通过动态测试和系统识别来评估轴力和拉杆的拉伸应力。在米兰大教堂的动态评估动态评估中采用的方法描述后,本文提出了在领带杆中的基本频率和轴向力方面进行了调查的主要结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号