The force situation of pole was analyzed in detail through the establishment of three-pole model, and the five-pole model was built on the basis of the former model. Besides, the influence of external factors including height difference, span, wind angle and line angle to the pole were studied, and the method to improve the force situation of pole: changing the pole arrangement styles was concluded in the research. At the end of the paper, the important points of "abandoning lines to protect electric poles" project were explained and illustrated by an example of implementation. It offered theoretical support to the implementation of "abandoning wires to protect poles" project.
机译:通过建立三极模型详细分析了极点的力情况,并在前模型的基础上建立了五极模型。此外,研究了外部因素,包括高度差,跨度,风角和线角对杆的影响,以及提高杆力情况的方法:在研究中结束了杆子排列态度。在本文结束时,通过实施例说明和说明了“保护电极的放弃线”项目的重要点。它为实施“放弃电线保护杆”项目提供了理论支持。