Comparison between PEMFC Water Management Model and in-situ Water Transfer Measurements

机译:PEMFC水管理模型与原位水转量测量的比较

获取原文

摘要

This work describes the design steps and demonstrates the capabilities of a novel water transfer factor measurement apparatus for the purpose of experimental analysis, water management model validation and tailoring. Several measurement concepts were screened on the basis of their water transfer factor accuracy using a Monte-Carlo approach. The most promising concept was assembled and tested to assess its actual measurement accuracy. Combining cathode and anode measurements, the simulated water transfer factor accuracy was typically better than ±0.01. The measurement strategy was finally implemented on a real PEMFC and several series of tests were conducted. Experimental data was in good agreement with a recently proposed model under moderately high pressure (200 kPa) and current densities (above 0.3 A/cm~2), but indicates that the model tends to underestimate the back diffusion of the water from the cathode to the anode especially at low current densities.
机译:这项工作描述了设计步骤,并演示了用于实验分析,水管理模型验证和剪裁的新型水转移因子测量装置的能力。使用Monte-Carlo方法基于其水转印因子精度筛选几种测量概念。最有希望的概念被组装并测试以评估其实际测量精度。组合阴极和阳极测量,模拟的水转印因子精度通常优于±0.01。最终在真实的PEMFC上实施测量策略,并进行了几系列测试。实验数据与最近提出的模型在中等高压(200kPa)和电流密度(高于0.3A / cm〜2)下吻合良好,但表明该模型倾向于低估水从阴极到阴极扩散阳极尤其是低电流密度。