Multi-Analyte, Fiber-Optic Immuno-Biosensor with Automatic Control System for Rapid Anticoagulant Deficiency Diagnosis

机译:具有自动控制系统的多分析物,光纤免疫生物传感器,用于快速抗凝缺陷诊断

获取原文

摘要

Protein C (PC), protein S (PS), antithrombin III (ATIII), and plasminogen (PLG) are four major anticoagulants in blood plasma. Deficiency of any of these anticoagulants may lead to venous thromboembolism (VTE), including heart attack, stroke, and lung embolism. Early diagnosis is critical to prevent the fatal VTE complications. To simultaneously quantify multi-anticoagulants in one assay for rapid and accurate disease diagnosis by the multi-biomarker information, a fiber-optic, multi-analyte immuno-biosensing system has been developed. Individual sensors were developed separately and the sensing protocol was optimized with the application of convective flow during the sample and reagent incubations. Convection facilitates the mass transport of analyte and reagent molecules to the sensor surface by reducing boundary layer thickness and the sensitivity of the sensors was significantly improved for samples with high viscosity (i.e. plasma). The optimal flow velocity for anticoagulant sensing was determined to be 0.7 cm/s, where the reaction kinetics changes from the mass-transportlimited to the reaction-limited. At the optimal flow velocities, the sensor size was reduced to 3 cm and the assay time was optimized to be 5 minutes. For the simultaneous four-factor quantification, four sensors were connected in series in a four-analyte sensing unit. The sensors demonstrated high specificity with minimal cross-reactivity to other analytes in the sample. The multi-anticoagulant sensing system was capable of quantifying PC, PS, ATIII, and PLG in their sensing ranges within 5 minutes, at an average signal-to-noise (S/N) ratio of 25. To make the sensing procedures more userfriendly, a prototype of an automatic flow control system consisting of electrical micro-pump and microvalves was developed. A LabviewTM program was written to automatically perform the predetermined sensing procedures for simultaneous four-analyte quantification. This system is beneficial for clinicians to diagnose diseases rapidly, easily, and cost-effectively and to design an accurate patient care strategy from the multiple biomarker information. The principle of the multi-analyte detection in this system can also be applied for simultaneous monitoring of other disease-representing biomarkers, such as, tumor markers for cancer detection. This project is funded by the National Science Foundation (BES- 0330075).
机译:蛋白C(PC),蛋白质S(PS),抗凝血酶III(ATIII)和纤溶酶原(PLG)是血浆中的四个主要抗凝血剂。任何这些抗凝血剂的缺乏可能导致静脉血栓栓塞(VTE),包括心脏病发作,中风和肺栓塞。早期诊断对于预防致命的VTE并发症至关重要。为了在一个测定中同时量化多抗凝剂,用于通过多生物标志物信息快速和准确的疾病诊断,已经开发了纤维 - 光学,多分析物免疫生物传感系统。单独开发各个传感器,并在样品和试剂孵育期间使用对流流动进行优化的感测方案。对流通过降低边界层厚度,促进分析物和试剂分子对传感器表面的质量传输,并且对于具有高粘度的样品(即血浆)的样品显着改善了传感器的灵敏度。抗凝血感测的最佳流速测定为0.7cm / s,其中反应动力学从质量传递到反应有限的变化。在最佳流速下,传感器尺寸降低至3cm,测定时间优化为5分钟。对于同时的四因子量化,四个传感器在四分之一的四分音传感单元中串联连接。传感器对样品中的其他分析物具有最小的交叉反应性表现出高的特异性。多抗凝感测系统能够在5分钟内定量PC,PS,ATIII和PLG在5分钟内,平均信号对噪声(S / N)比例为25。使传感程序更用户友好,开发了由电气微泵和微型阀组成的自动流量控制系统的原型。写入LabViewTM程序以自动执行用于同时四分之一分析物量化的预定感测程序。该系统有利于临床医生快速,容易,且成本有效地诊断疾病,并从多种生物标志物信息设计精确的患者护理策略。该系统中多分析物检测的原理也可用于同时监测其他疾病代表的生物标志物,例如癌症检测的肿瘤标志物。该项目由国家科学基金会资助(BES-030075)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号