China Spallation Neutron Source(CSNS) cryogenic system provides supercritical cryogenic hydrogen to neutron moderators, including a helium refrigerator, hydrogen loop and hydrogen safety equipment. The helium refrigerator is provided by Linde with cooling capacity of 2200 W at 20 K. Hydrogen loop system mainly includes cryogenic hydrogen pipes, hydrogen circulator cold-box and accumulator cold-box. Cryogenic hydrogen pump, ortho-para converter, helium-hydrogen heat-exchanger, hydrogen heater and accumulator are integrated in hydrogen circulation cold-box, and accumulator cold-box. Hydrogen safety equipment includes safety valves, rupture disk, hydrogen sensor, flame detector and other equipment to ensure that cryogenic system in dangerous situations will go down, vents, or takes other measures. The cryogenic system commissioning work includes four steps. First, in order to test the refrigerating capacity of refrigerator, when acceptance testing, refrigerator internal heater was used as thermal load. Second, using simulation load as heat load of moderator, hydrogen loop use helium instead of hydrogen, and cooled down to 20 K, then re-warming and test the leak detection of hydrogen loop system. Third, base on the step 2, using hydrogen as working medium, and optimized the control logic. Forth, cryogenic system with the moderators joint commissioning. Now, cryogenic system is connected with the moderators, and the forth step will be carried out in the near future.
机译:中国散发中子源(CSNS)低温系统提供超临界低温氢以中子式调节剂,包括氦冰箱,氢气环和氢气安全设备。氦冰箱由林德提供2200W的林德,20K氢环系统主要包括低温氢气管,氢循环冷箱和蓄电池冷箱。低温氢气泵,Ortho-Para转换器,氦气热交换器,氢气加热器和蓄电池集成在氢循环冷箱中,蓄电池冷箱。氢气安全设备包括安全阀,破裂盘,氢气传感器,火焰探测器和其他设备,以确保危险情况下的低温系统将下降,通风口或采取其他措施。低温系统调试工作包括四个步骤。首先,为了测试冰箱的制冷能力,当验收测试时,冰箱内加热器用作热负荷。其次,使用模拟负载作为主持人的热负荷,氢气环使用氦代替氢气,并冷却至20 k,然后重新加热并测试氢气环系统的泄漏检测。第三,基于步骤2,使用氢作为工作介质,并优化控制逻辑。第四,低温系统与主持人联合调试。现在,低温系统与主持人连接,并将在不久的将来进行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号