摘要

This paper analyzes the zero and first order pressure drop along the pulse tube system and presents a simple but elegant way of eliminating the third type of DC gas flow which increases the efficiency of a Stirling type PTC. Since the optimization of a PTC depends sensitively on the adjustment of the phase angle between the pressure and mass flow because of its influence on the suppression of the third type of DC gas flow, we have done a series of experiments on a Stirling type multi-bypass PTC in order to attain the lowest refrigeration temperature. After the multi-bypass PTC reaches its lowest temperature, we open the metering valve to the best degree which connects the back pressure chamber of the linear compressor to the reservoir. For this novel type of PTC, the lowest refrigeration temperature drops from 38.8 K to 25.9 K after opening the metering valve. This approach offers a promising way for a compact single stage Stirling type PTC to reach liquid hydrogen temperatures.
机译:本文分析了脉冲管系统的零和一阶压力下降,并提出了一种简单但优雅的方式,可以消除增加斯特林型PTC效率的三种直流气流。由于PTC的优化敏感地取决于压力和质量流量之间的相位角的调节,因为它对抑制第三种直流气流的抑制,我们已经在斯特林型多级实验完成了一系列实验绕过PTC以获得最低的制冷温度。多旁路PTC达到其最低温度后,我们将计量阀打开到最佳程度,该最佳程度将线性压缩机的背压室连接到储存器。对于这种新型PTC,最低的制冷温度在打开计量阀后从38.8k到25.9 k下降。这种方法为紧凑的单级斯特林PTC提供了一种有希望的方式,以实现液体氢气温度。