首页> 外文会议>Cryogenic Engineering Conference >DEVELOPMENT OF EXPERIMENTAL SETUP FOR STUDY OF ADSORPTION CHARACTERISTICS OF POROUS MATERIALS DOWN TO 4.2 K
【24h】

DEVELOPMENT OF EXPERIMENTAL SETUP FOR STUDY OF ADSORPTION CHARACTERISTICS OF POROUS MATERIALS DOWN TO 4.2 K

机译:实验设置研究多孔材料的吸附特性降至4.2 k

获取原文

摘要

The knowledge of adsorption characteristics of activated carbon (porous material) in the temperature range from 5 to 20 K is essential when used in cryosorption pumps for nuclear fusion applications. However, such experimental data are very scarce in the literature, especially below 77 K. So, an experimental system is designed and fabricated to measure the adsorption characteristics of porous materials under variable cryogenic temperatures (from 5 K to 100 K). This is based on the commercially available micropore-analyser coupled to a closed helium cycle two-stage Gifford McMahon (GM) Cryocooler, which allows the sample to be cooled to 4.2 K. The sample port is coupled to the Cryocooler through a heat switch, which isolates this port from the cold head of the Cryocooler. By this, the sample temperature can now be varied without affecting the Cryocooler. The setup enables adsorption studies in the pressure range from atmospheric down to 10~(-4) Pa. The paper describes the details of the experimental setup and presents the results of adsorption studies at 77 K for activated carbon with nitrogen as adsorbate. The system integration is now completed to enable adsorption studies at 4.2 K.
机译:当用于核融合应用的冷热泵时,温度范围内的活性炭(多孔材料)的吸附特性的知识是必需的。然而,这些实验数据在文献中非常稀缺,特别是低于77k。因此,设计并制造了一种实验系统,以测量可变低温温度下多孔材料的吸附特性(从5 k到100k)。这是基于市售的微孔分析仪,其连接到封闭的氦循环两级Gifford McMahon(GM)低温器,其允许样品冷却至4.2k.样品端口通过热开关耦合到低温冷却器,其中将该端口与冷冻机的冷头隔离。由此,现在可以改变样品温度而不会影响低温冷却器。该设置使得压力范围内的吸附研究从大气压下降到10〜(-4)PA。本文介绍了实验设置的细节,并以77K为77K的吸附研究结果,以氮气为吸附性碳。现在完成系统集成,以便在4.2 k下启用吸附研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号