The direct verification and the calibration of Rockwell diamond cone indenters in NMIJ and JBI are described. Developed installment can verify the roundness of the spherical part of the indenters, measure the radius of indenter tip and the cone angle by the optical methods. The regression analysis of the geometry of indenters and hardness value can determine the bias of each indenter in each hardness level. This bias can be used to correct the hardness value. To investigate the availability of the correction of hardness value, the experiments were carried out to analyze the relation between the indenters and other treating conditions. The results show that the effect of indenters is independent with other factors and the correction of hardness values are available. Hardness values were agreed within 0.04 HRC (standard deviation) after the correction is was applied.
机译:描述了NMIJ和JBI中Rockwell金刚石锥形压痕的直接验证和校准。开发的安装可以验证压头的球形部分的圆度,通过光学方法测量压头尖端和锥角的半径。压痕和硬度值的几何形状的回归分析可以确定每个硬度水平中的每个压痕的偏差。该偏差可用于校正硬度值。为了研究硬度值校正的可用性,进行实验以分析压痕和其他治疗条件之间的关系。结果表明,压头的效果与其他因素无关,并且可获得硬度值的校正。在施加校正后,在0.04HRC(标准偏差)之内同意硬度值。