首页> 外文会议>International Symposium on Safety Science and Technology >Experimental research on minimum ignition temperature of 7-ACA dust cloud
【24h】

Experimental research on minimum ignition temperature of 7-ACA dust cloud

机译:7-ACA尘埃云最小点火温度的实验研究

获取原文

摘要

7-aminocephalosporanic acid (7-ACA) is the key intermediate powder to product cephalosporin. The ignition temperature test device (NU-TC1000) for dust cloud was used to test the minimum ignition temperature of 7-ACA dust cloud. When the dispersion mass of 7-ACA dust is 0.8g, the minimum ignition temperature of dust cloud is 496 °C. The minimum ignition temperature increases first and then reduces with the increase of dispersion mass. When 7-ACA and acetone are mixed in the ratio of 1g 7-ACA plus 0.75ml acetone and the dispersion mass of mixture sample is 0.6g, the minimum ignition temperature of dust cloud is 400 °C. Experimental results show that the minimum ignition temperature of dust cloud decreases markedly by adding acetone into 7-ACA dust. How to set powder has a quite influence on the results.
机译:7-氨基膦酸(7-ACA)是产品头孢菌素的关键中间粉末。用于灰尘云的点火温度测试装置(NU-TC1000)用于测试7-ACA粉尘云的最小点火温度。当7-ACA粉尘的分散质量为0.8g时,粉尘云的最小点火温度为496℃。最小点火温度首先增加,然后随着分散质量的增加而减小。当7-ACA和丙酮混合1G 7-ACA加0.75ml丙酮的比例和混合物样品的分散质量为0.6g时,粉尘云的最小点火温度为400℃。实验结果表明,通过将丙酮添加到7 aca灰尘,粉尘云的最小点火温度明显减少。如何设置粉末对结果有相当影响。