Based on actual measurements in our own developed Super Nano-Cleanroom (floor area: 47 m~2), a comparison between 0 percent and 45 percent relative humidities revealed a slight difference in concentration of both gaseous organic compounds and ionic constituents in the air. This study examined and evaluated changes in the emission rate of outgases from some of the constitute materials for a clean room, which may occur depending on humidity conditions. Results showed no significant differences in emission rates of gaseous organic compounds and Cl~- at between 0 percent and 45 percent relative humidity. However, ammonia showed a tendency to have a slightly lower emission rate at 0 percent relative humidity than that at 45 percent. This is considered to be derived from less moisture being absorbed onto the surface of materials, resulting in a reduced transfer rate of ammonia from inside the material to the material surface.
机译:基于我们自己开发的超级纳米洁净室(楼层区域:47m〜2)的实际测量,比较0%至45%的相对湿度揭示了空气中气态有机化合物和离子成分的浓度略微差异。本研究检查并评估了来自一些构成材料的洁净室的出版物排放率的变化,这可能取决于湿度条件。结果表明,气态有机化合物和Cl〜 - 45%相对湿度的排放率没有显着差异。然而,氨表明,在0%相对湿度下的发射率略低于45%。这被认为是从吸收到材料表面上的较少的水分衍生,导致从材料内部的氨的转移速率降低到材料表面。