首页> 外文会议>Society of Photo-Optical Instrumentation Engineers Conference on Medical Imaging : Physiology and Function--Methods, Systems, and Applications >In Vivo Regional Myocardial Perfusion Measurements in a Porcine Model by ECG-Gated Multi-Slice Computed Tomography
【24h】

In Vivo Regional Myocardial Perfusion Measurements in a Porcine Model by ECG-Gated Multi-Slice Computed Tomography

机译:通过ECG门控多切片计算机断层扫描的猪模型中的体内区域心肌灌注测量

获取原文

摘要

Purpose: To evaluate whether functional multi-slice computed tomography (MSCT) can identify regional areas of normally perfused and ischemic myocardium in a porcine model. Material and Methods: Three out bred pigs, two of which had ameroids surgically implanted to constrict flow within the LAD and LCx coronary arteries, were injected with 25 mL of iopromide (Isovue) at a rate of 5 mL/second via the femoral or jugular vein. Sixty axial scans along the short axis of the heart was acquired on a 16-slice CT scanner (Philips MX8000-IDT) triggered at end-diastole of the cardiac cycle and acquiring an image within 270 msec. A second series of scans were taken after an intravenous injection of a vasodilator, 150 μg/kg/min of adenosine. ROIs were drawn around the myocardial tissue and the resulting time-density curves were used to extract perfusion values. Results: Determination of the myocardial perfusion and fractional blood volume implementing three different perfusion models. A 5-point averaging or 'smoothing' algorithm was employed to effectively filter the data due to its noisy nature. The (preliminary) average perfusion and fractional blood volume values over selected axial slices for the pig without an artificially induced stenosis were measured to be 84 +/- 22 mL/min/100g-tissue and 0.17 +/- 0.04 mL/g-tissue, the former is consistent with PET scan and EBCT results. The pig with a stenosis in the left LAD coronary artery showed a reduced global perfusion value--45 mL/min/100g-tissue. Correlations in regional perfusion values relative to the stenosis were weak. During the infusion of adenosine, averaged perfusion values for the three subjects increased by 46 (+/-45) percent, compatible to increases measured with PET. Conclusion: Quantifying global perfusion values using MDCT appear encouraging. Future work will focus resolving the systematic effects from noise due to signal fluctuation from the porcine tachyardia (80-93 BPM) and provide a more robust measurement of regional myocardial perfusion throughout the heart.
机译:目的:评估功能性多切片计算机断层扫描(MSCT)是否可以在猪模型中识别正常灌注和缺血心肌的区域区域。材料和方法:三种繁殖的猪,其中两只植物术植入小组和LCX冠状动脉内的流动,以5ml /秒的速率通过股骨或颈静脉注射25ml IOPROMIDE(Isovue)静脉。沿着心脏短轴的六十轴向扫描在心脏周期的末端舒张末端触发的16切片CT扫描仪(飞利浦MX8000-IDT)上获得,并在270毫秒内获取图像。在静脉注射血管扩张剂,150μg/ kg / min后,采用第二系列扫描。在心肌组织周围绘制rOI,得到的时间密度曲线用于提取灌注值。结果:测定心肌灌注和分数血量,实现三种不同的灌注模型。采用5分平均或“平滑”算法,以有效地过滤数据由于其嘈杂的性质。测量没有人工诱导的狭窄的猪的所选轴向切片上的(初步)平均灌注和分数血量值为84 +/- 22ml / min / 100g-组织和0.17 +/- 0.04ml / g组织,前者与PET扫描和EBCT结果一致。左侧冠状动脉狭窄的猪显示出全球灌注值的减少 - 45ml / min / 100g组织。区域灌注值相对于狭窄的相关性弱。在输注腺苷期间,三个受试者的平均灌注值增加46(+/- 45)%,与PET测量的增加相容。结论:使用MDCT量化全球灌注值看起来令人鼓舞。未来的工作将焦点由于来自猪Tacrcine(80-93bpm)的信号波动而重构噪声的系统效应,并在整个心脏中提供更强大的区域心肌灌注。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号