Behavior of steel beam to circular CFT column connections

机译:钢梁到圆形CFT列连接的行为

获取原文

摘要

This paper describes the structural behavior of connections between concrete-filled tubular (CFT) steel column and steel beam. The connections are characterized with the flange plates penetrated through the column. Four beam-to-column subassemblage specimens were tested under reversal loading. Specimens with strong shear capacity in the panel zone demonstrated stable hysteresis behavior by forming the plastic hinge in the beam. Specimen having panel zone shear yielding resulted in pinching hysteresis curve, which was caused by the diagonal shear cracking of the concrete inside the steel tube. The shear capacity of the CFT column in the panel zone is contributed from the steel tube and concrete core and can be estimated by superposition of the strengths of the steel tube and the concrete.
机译:本文介绍了混凝土管状(CFT)钢柱和钢梁之间连接的结构行为。连接的特征在于凸缘板穿过柱子。在逆转载荷下测试四个梁到柱子组件标本。通过在梁中形成塑料铰链,面板区域中具有强剪切容量的标本证明了稳定的滞后行为。具有面板区剪切产生的样本导致夹磁曲线,这是由钢管内混凝土的对角线剪切裂纹引起的。面板区域中的CFT柱的剪切容量从钢管和混凝土芯中贡献,可以通过叠加钢管和混凝土的优点来估计。

著录项