首页> 外文会议>SPIE Conference on Advanced optical Devices, Technologies, and Medical Applications >Skin blood flow changes during local arm heating: comparison between the laser-Doppler and frequency-corrected thermal clearance measurement
【24h】

Skin blood flow changes during local arm heating: comparison between the laser-Doppler and frequency-corrected thermal clearance measurement

机译:局部臂加热期间皮肤血流变化:激光多普勒与频率校正热间隙测量之间的比较

获取原文

摘要

We compared two different techniques for non-invasive registration of fingertip skin blood flow changes in 5 healthy volunteers during local arm heating in the water bath from 21 °C to 42 °C. The laser-Doppler flowmetry (LDF) probe was attached to the pulp of the index finger, while the thermal clearance (TC) probe was fixed to the pulp of the middle finger. Computer simulation method, provided by the MATLAB package, was introduced to speed up the frequency response of the TC probe. By correlation analysis we evaluated the similarity of LDF and TC recordings. The median correlation coefficient for the relationship LDF versus TC equaled 0.74, the range being from 0.63 to 0.82. After an introduction of the computer-based frequency correction, the correlation increased till 0.88 with the range from 0.82 to 0.91. The corresponding improvement in r~2 ("goodness to fit") was 41%.
机译:我们比较了两种不同的技术用于指尖皮肤血流的非侵入性登记,在局部臂在水浴中从21°C加热到42°C时5个健康志愿者的变化。激光 - 多普勒流动(LDF)探针连接到食指的纸浆上,而热间隙(Tc)探针固定在中指的纸浆上。通过MATLAB包提供的计算机仿真方法,引入了加快TC探头的频率响应。通过相关性分析,我们评估了LDF和TC录像的相似性。关系的中值相关系数LDF与Tc等于0.74,范围为0.63至0.82。在引入基于计算机的频率校正之后,相关性增加到0.88,范围为0.82至0.91。 R〜2的相应改善(“健康”)为41%。