首页> 外文会议>Geothermal Resources Council Annual Meeting >F3680 Silica Inhibitor Testing in Botong Sector, Bacon-Manito Geothermal Production Field, Philippines
【24h】

F3680 Silica Inhibitor Testing in Botong Sector, Bacon-Manito Geothermal Production Field, Philippines

机译:F3680二氧化硅抑制剂检测博孔部门,培斯邦地热生产领域,菲律宾

获取原文

摘要

A polyacrylic copolymer based silica inhibitor (F3680), were tested at varying concentrations from 5-20 ppm using Botong separated brine at 0.70 MPa with about 45percent oversaturation with respect to amorphous silica to determine its efficiency and inhibition property at the current cold injection set-up. Geogard SX (GSX), the existing silica inhibitor being used by the Botong Reinjection System (BRS) was also tested in the same set-up to compare the two inhibitors and determine if F3680 can be used as an alternative to GSX. The chemical inhibitor was dosed at the two-phase fluid tapped from the header of all production wells before the main separator. F3680 reduces silica deposition within the cold section of BRS with an average deposition rates ranging from 1.76 to 2.76 mm/ day as compared to 3.98 mm/day of the untreated line. Treating the brine with 10ppm of F3680 achieved the highest inhibition efficiency of 55.8percent. Brine treated with F3680 produced poorly formed, layered, and thin but moderately hard silica deposits, to granular and compact and soft gel-type that settles and friable. GSX treated brine produced silica deposits that are much more dense, very hard, and massive. The deposits are also adherent to the metal surface and alter to globular and grainy habits downstream of the test facility. Average deposition rate of GSX-treated brine is 1.27 mm/day, which is higher than any concentration of F3680 treated brine. The efficiency is consequently higher at 68percent. Results of the tests using F3680 is promising and can be used to replace GSX as long as regular cleaning of the sumps will be implemented.
机译:基于聚丙烯共聚物的二氧化硅抑制剂(F3680),在0.70MPa的5-20mPm的不同浓度下以0.70MPa的0.70MPP的过饱和相对于无定形二氧化硅,以确定其在当前冷注射套件的效率和抑制性能的情况下进行测试。向上。 GeoGard SX(GSX),肉杆再注体(BRS)使用的现有二氧化硅抑制剂也在相同的设置中进行测试,以比较两种抑制剂并确定F3680是否可以用作GSX的替代方案。将化学抑制剂在主体分离器之前从所有生产孔的集管中汲取的两相液中。 F3680在BRS的冷截面内减少二氧化硅沉积,平均沉积速率范围为1.76至2.76毫米/天/天,相比未处理的线3.98毫米/天。用10ppm处理F3680的盐水最高抑制效率为55.5%。用F3680处理的盐水产生不良,层状,薄但适度的硬性二氧化硅沉积物,颗粒和紧凑且柔软的凝胶型,可沉降和易碎。 GSX处理的盐水产生的二氧化硅沉积物更密集,非常坚硬和巨大。沉积物也依赖于金属表面,并改变测试设施下游的球状和颗粒状习惯。 GSX处理的盐水的平均沉积速率为1.27mm /天,高于F3680处理的盐水的任何浓度。因此,效率在68平方米较高。使用F3680的测试结果是有前途的,只要将实现水槽的定期清洁,就可以用来代替GSX。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号