A membrane-separation system for continual removal of non-condensable gases from binary plant condenser vapor has been built and is undergoing testing. Previous reports have described its principles of operation, design, and results of testing in an isopentane-working-fluid unit. These results indicated that the unit is capable of maintaining a low noncondensable gas inventory in the plant condenser. In addition, loss of working fluid resulting from condenser-purging operations was reduced to a fraction of its previous value through use of the continuous removal system. Tests being performed in an isobutane-working-fluid plant have indicated that system modification is needed for unattended long-term operation. These modifications were made in April/May 2004, and testing has resumed. The host plant currently operates with a severe, atypical air intake rate, testing the removal system's performance at a purge rate several times its design operation. This paper reports the results of the ongoing tests.
机译:构建并正在建立一种膜分离系统,用于连续去除来自二元植物冷凝器蒸气的不可冷凝气体。正在进行测试。以前的报告已经描述了其在等络作用流体单元中的操作,设计和测试结果原理。这些结果表明该单元能够在植物冷凝器中保持低不可调味的气体清单。另外,通过使用连续的去除系统,将冷凝器吹扫操作导致的工作流体的损失降低到其先前值的一小部分。在异丁烷 - 工作流体工厂中进行的测试表明,无人值守的长期操作需要系统改性。这些修改是在2004年4月/ 5月进行的,并且测试已恢复。主机工厂目前以严重的非典型进气率运行,以吹扫速率测试清除系统的性能多次设计操作。本文报告了正在进行的测试的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号