Recently adopted ASTM Standard Test E 1886-97, "Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Storm Shutters Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials" and its accompanying specification, E 1996-99, "Standard Specification for Performance of Exterior Windows, Glazed Curtain Walls, Doors, and Storm Shutters Impacted by Windborne Debris in Hurricanes" are used to determine the the performance of exterior fenestration elements when subjected to hurricane-like conditions. The intent of these standards is to minimize property or personal loss due to the breaching of fenestration elements in a hurricane. Protective systems for both new and existing buildings have been developed in response to these new standards. One possible application for existing building glass is an anchored-film system. This system relies on a polyester film adhered to the existing glass. The film is anchored around the glass perimeter to the window frame. An existing building with a history of thermal stress glass breakage required a system to safeguard against the possibility of glass fallout. Testing was necessary to determine the effectiveness of an anchored-film system for this application. The aforementioned ASTM standards were consulted; however, the cause of cracking, the nature of anticipated wind loads, and the pass/fail criteria were significantly different from those presented in these standards. Test criteria were developed by the authors to simulate the cracked glass, to apply appropriate loads and to measure the degree of fallout protection. This paper summarizes the development, implementation, and results of the test program, thereby demonstrating the feasibility and effectiveness of anchored-film systems for this unique application.
机译:最近采用了ASTM标准测试E 1886-97,“由导弹影响的外墙,幕墙,门和风暴百叶窗的标准测试方法,并暴露于循环压差”及其随附的规范,E 1996-99 ,“外部窗户的性能标准规范,普遍存在的外部窗帘墙壁,门和风暴百叶窗受到飓风中的Windborne碎片的影响”,用于确定飓风状况时外部更eneptration元素的性能。这些标准的目的是最大限度地减少由于飓风中的更新元素突破了财产或个人损失。为响应这些新标准而开发了新的和现有建筑物的保护系统。现有建筑玻璃的一种可能施加是一种锚固薄膜系统。该系统依赖于粘附在现有玻璃上的聚酯薄膜上。薄膜围绕玻璃周边锚定到窗框。具有热应力玻璃破损历史的现有建筑物需要一个系统来保护玻璃辐射的可能性。需要测试以确定本申请的锚固膜系统的有效性。上述ASTM标准是咨询的;然而,裂缝的原因,预期的风力载荷的性质以及通过/失效标准的性质与这些标准中提出的显着不同。作者开发了测试标准以模拟裂纹玻璃,施加适当的载荷并测量辐射保护程度。本文总结了测试计划的开发,实施和结果,从而证明了锚固薄膜系统的可行性和有效性为该独特的应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号