摘要

During a test program on a modern heavy-duty engine, measurements were made at engine-out and tailpipe of particle number and particulate mass using the draft heavy-duty, inter-laboratory correlation exercise guide prepared by the UN-ECE Particle Measurement Program (PMP). In addition to the PMP measurements, the elemental carbon content of the particulate matter from this program was analyzed using thermogravimetric analysis of separate filters.
机译:在现代重型发动机的测试程序期间,使用由UN-ECE粒子测量程序制备的重型实验室的粒子数和颗粒物质的颗粒数和颗粒物质的尾气管道测量( PMP)。除PMP测量外,使用单独过滤器的热重分析分析来自该程序的颗粒物质的元素碳含量。