In the field of image-guided surgery, registration of pre- and intra-operative images is an important, yet sometimes cumbersome procedure. Visual matching, consisting of a manual alignment of such images can improve the efficiency of registration. In this paper we investigate the accuracy of a visual matching system. A number of tests, including mono and stereo visualization of real and virtual objects, was set up. Seven test subjects were asked to register pre-and intra-operative images while accuracy and registration time were measured. The error analysis led to the conclusion that one can accurately match a virtual phantom with a real one in directions perpendicular to the viewing direction. The depth accuracy though is insufficient for registration purposes, even when using stereo perception. We conclude that visual matching can be complementary to more automatic registration methods or even a valuable alternative in applications where the viewing directions are nearly perpendicular as in bi-plane fluoroscopy.
机译:在图像引导手术领域,预先和术语图像的登记是一个重要的,但有时有时繁琐的程序。视觉匹配,由这种图像的手动对齐组成,可以提高注册效率。在本文中,我们研究了视觉匹配系统的准确性。建立了许多测试,包括Mono和实体和虚拟对象的立体声可视化。要求七个测试对象注册预先绘制的图像,同时测量精度和注册时间。误差分析导致得出结论,可以在垂直于观察方向的方向上使用真正的一个能够准确地匹配虚拟幻像。即使使用立体声感知,也不足以进行登记目的的深度精度。我们得出结论,视觉匹配可以与更多自动登记方法互补,甚至可以在观察方向几乎与双平面荧光透视中垂直的应用中的有价值的替代方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号