A new spectrometer has been developed, including a pencil-beam 14-MeV neutron source and a telescope system with two SSDs of E and E, in order to measure double differential charged-particle emission cross sections (DDXs). The spectrometer can supply quite good performance, i.e., low minimum measurable energy of below 2 MeV for alpha particles and a very high S/N ratio over 10. Highly accurate charged-particle emission DDX data can thus be expected to be measured by this spectrometer. From the test measurement for aluminum, the validity was confirmed by comparing the angular differential cross section (ADX) and the total charged-particle emission cross section with other data. Also, the measurement for beryllium has been carried out. From the result of the measurement, the acceptable agreement with the evaluation was confirmed in the energy spectrum. The precise branching ratio of the breakup nuclear reaction of beryllium is now being analyzed from the obtained DDX data.
机译:已经开发了一种新的光谱仪,包括铅笔束14-MEV中子源和具有两个E和E的SSD的望远镜系统,以测量双差分电荷粒子发射横截面(DDX)。光谱仪可以提供相当良好的性能,即,对于α颗粒,低于2MeV的低最小可测量能量,并且可以通过该光谱仪测量高度精确的充电粒子发射DDX数据。通过该光谱仪可以测量非常高的S / N比。 。从铝的测试测量,通过将角差分横截面(ADX)和总充电粒子发射截面与其他数据进行比较来确认有效性。此外,已经进行了铍的测量。从测量结果,在能谱中确认了与评估的可接受协议。现在从获得的DDX数据分析铍分解核反应的精确支化比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号