首页> 外文会议>International Workshop on Medical Imaging and Augmented Reality >A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data
【24h】

A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

机译:基于基于3D PET数据心运动校正的光学流法方法

获取原文

摘要

Cardiac Motion artifacts in PET are a well known problem. The heart undergoes two types of motion, the motion due to respiratory displacement and the motion due to cardiac contraction. These movements lead to blurring of data and to inaccuracies in the quantification. In this study a continuity equation based optical flow method is presented and results on 3D PET patient datasets for cardiac motion correction are presented. The method was evaluated with respect to three criteria: correlation between the images, myocardial thickness and the blood pool activity curves. The results showed that the method was successful in motion correcting the data with high precision.
机译:宠物中的心动术术是众所周知的问题。心脏经历了两种类型的运动,由于心脏收缩引起的呼吸位移和运动引起的运动。这些动作导致数据模糊并在量化中的不准确性。在本研究中,呈现了基于连续性方程的光学流法,并提出了用于心动校正的3D宠物患者数据集。根据三个标准评估该方法:图像,心肌厚度与血液池活性曲线之间的相关性。结果表明,该方法在运动中成功地校正了高精度的数据。