首页> 外文会议>International Conference on Lightning and Static Electricity >Factors affecting the position of interception of an electrical discharge from a rod to the ground in a gap containing grounded conductors at a short distance over the ground level
【24h】

Factors affecting the position of interception of an electrical discharge from a rod to the ground in a gap containing grounded conductors at a short distance over the ground level

机译:影响从杆从杆到地面的间隙中从杆拦截到地面的因素在含有接地导体的间隙上,在地面的短距离下

获取原文

摘要

In this paper, the results of the laboratory investigations concerning the probability of intercepting a lightning discharge by grounded metallic objects laying close to the surface of the soil are presented. The main parameters which have been investigated in the high-voltage laboratory are the soil resistivity and the distances from the ground as well as between the two grounded parallel conductors introduced in a short rod-plane gap and stressed by positive impulse voltages 2/40 ms. Under certain presuppositions the results of this investigation can be extrapolated for estimating the probability of a lightning discharge to strike a landed, parked aircraft in an airport. The results have proved an influence of the soil resistivity as well as of the distance between the two grounded conductors on the relative probability of a breakdown to be intercepted by these conductors.
机译:在本文中,提出了关于靠近土壤表面的接地金属物体拦截雷电放电概率的实验室研究结果。在高压实验室中研究的主要参数是土壤电阻率和地面的距离以及在短杆平面间隙中引入的两个接地平行导体,并由正脉冲电压强调2/40 ms 。在某些预设下,可以推断出该调查的结果,以估计避雷放电的概率,以在机场击打着落地的停放飞机。结果证明了土壤电阻率以及两个接地导体之间的距离对这些导体截取的击穿的相对概率的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有