In the period from April to October of 1988, a series of welding operations on the outside of the AZ Tank Farm ventilation line piping at the Hanford Site produced unexpected and repeated cracking of the austenitic stainless steel base metal and of a seam weld in the pipe. The ventilation line is fabricated from type 304L stainless steel pipe of 24-inch (60.96 cm) diameter and 0.25-inch (0.64 cm) wall thickness. The pipe was wrapped in polyethylene bubble wrap and buried approximately 12 feet (3.66 m) below grade. Except for the time period between 1980 and 1987, impressed current cathodic protection has been applied to the pipe since its installation in 1974. The paper describes the history of the cracking of the pipe, the probable cracking mechanisms, and the recommended future action for repair/replacement of the pipe.
机译:在1988年4月至10月的期间,在汉福德站点的AZ坦克农场通风线外面的一系列焊接操作在管道中产生了意外和反复开裂的奥氏体不锈钢基础金属和管道中的缝焊。通风线由24英寸(60.96cm)直径和0.25英寸(0.64cm)壁厚的304L不锈钢管制成。将管子用聚乙烯气泡包裹包裹,埋在等级以下约12英尺(3.66米)。除了1980年至1987年期间的时间段,自1974年安装以来,令人深受印象的电流阴极保护。本文介绍了管道开裂的历史,可能的裂缝机制,以及推荐的修理未来动作/更换管道。