首页> 外文会议>Conference on corrosion >Top of Line Corrosion- Diagnosis, Root Cause Analysis, and Treatment
【24h】

Top of Line Corrosion- Diagnosis, Root Cause Analysis, and Treatment

机译:顶部腐蚀 - 诊断,根本原因分析和治疗

获取原文

摘要

This paper details the processes used to respond to two Top of Line Corrosion (TLC) failures in a sour gas gathering system. The steps used to diagnose and remediate failures, including Root Cause Analysis, modeling of conditions, and changes to operating procedures are presented. The effect of gas cooling rate on water condensation, the pH of the condensed water, and the flow regime in each segment are discussed, as are their effect on the type of corrosion. The effectiveness of batch-filming and continuous inhibition in these lines is presented, as well as changes implemented after the failure incidents to improve corrosion management program effectiveness. Batch filming at proper intervals is shown to be an effective method for preventing TLC.
机译:本文详细介绍了用于响应酸气体聚集系统中的两条线腐蚀(TLC)故障的过程的过程。介绍了用于诊断和修复故障的步骤,包括根本原因分析,环境建模以及对操作程序的更改。讨论了气体冷却速率对水凝结的影响,冷凝水的pH和每个区段中的流动状态,它们对腐蚀类型的影响。展示了这些系列批量拍摄和连续抑制的有效性,以及在失败事件后实施的变化,以提高腐蚀管理计划效果。以适当的间隔分批拍摄是防止TLC的有效方法。