首页> 外文会议>ASME TURBO EXPO >DYNAMIC ANALYSIS OF COMPRESSOR TRIPS IN THE SNOHVIT LNG REFRIGERANT CIRCUITS
【24h】

DYNAMIC ANALYSIS OF COMPRESSOR TRIPS IN THE SNOHVIT LNG REFRIGERANT CIRCUITS

机译:Snohvit LNG制冷剂电路中压缩机跳闸的动态分析

获取原文

摘要

Compressors are key components in the refrigerant circuits of the Snohvit LNG plant and contain large amounts of mechanical energy. Thus it is imperative that the control system is able to keep the compressor out of surge in case of driver trip. A dynamic process simulator describing the total LNG plant has been developed by Kongsberg Process Simulation and the simulator has been applied in the engineering phase for the design and process verification. The simulator has also been used to verify the robustness of the closed loop refrigerant circuits and to verify that the refrigerant compressors are sufficiently protected after a driver trip. The presented work demonstrates the value of dynamic simulations for verification of compressor protection systems. In addition it shows the importance of using correct data for polar inertia of the rotating equipment, as well as the opening and dead times of the anti-surge valves. It is recommended to include a sensitivity analysis of these parameters as part of plant verification studies.
机译:压缩机是Snohvit LNG植物的制冷剂电路中的关键部件,并含有大量的机械能。因此,在驾驶员跳闸的情况下,控制系统必须将压缩机能够将压缩机放在浪涌。描述了描述总LNG工厂的动态过程模拟器由孔斯堡流程仿真开发,模拟器已应用于设计和过程验证的工程阶段。模拟器还用于验证闭环制冷剂电路的鲁棒性,并验证制冷剂压缩机在驾驶员跳闸后充分保护。所呈现的工作展示了动态模拟的值,以便验证压缩机保护系统。此外,它显示了使用旋转设备的极性惯性的正确数据的重要性,以及抗喘振阀的开口和死亡时间。建议将这些参数的敏感性分析作为植物验证研究的一部分。