Local electrochemical probes, the Scanning Vibrating Electrode Technique, the electrochemical capillary cell and a pH sensor have been used to study the corrosion behavior of zinc coated low alloy carbon steel cut-edges immersed in 0.03 M NaCl solution. Experimental results show an inhibition of cathodic reactions on a limited area of the steel surface. Hypothesis of self-healing on cut-edge has been tested and validated by two complementary numerical models of the corrosion behavior. Then a self-healing mechanism is proposed that explains obtained observations.
机译:局部电化学探针,扫描振动电极技术,电化学毛细管电池和pH传感器已经用于研究锌涂覆的低合金碳钢切割边缘浸入0.03M NaCl溶液中的腐蚀行为。实验结果显示抑制钢表面有限区域的阴极反应。通过两个腐蚀行为的两个互补数值模型进行了测试和验证了切割边缘上自愈合的假设。然后提出了一种解释获得观察的自我愈合机制。