The purpose of smoke proof design for high-rise building is to prevent harm from smoke and to control smoke-diffusing. The effective smoke-preventing installation should have the functions such as absolute smoke insulation, going into and coming off the smoke-preventing place freely, no confinement of sight. Through analyzing smoke-flow field theoretically, it is discussed that the effect of air flow on a high-rise building is as a result of gas expansion by the temperature, the chimney effect, the outdoor wind power and the ventilation and air-conditioning system when firing. The flow field at the staircase door is theoretically found. The way in which the diffusion of smoke is controlled is advanced according to the principle of flow line-flow rate and based on the previous experimental researches by others, the calculation method for the smoke-preventing air curtain is inferred in this paper.
机译:用于高层建筑的烟雾防范设计的目的是防止烟雾造成伤害并控制烟雾扩散。有效的防烟装置应具有绝对烟雾绝缘等功能,自由地进入和防止烟雾,没有矛盾。通过理论上分析烟雾流场,讨论了气流对高层建筑物的影响是由于温度,烟囱效应,室外风力和通风和空调系统的气体膨胀的结果射击时。理论上,楼梯门处的流场。控制烟雾扩散的方式是根据流量流速的原理提出,并基于其他人的实验研究,在本文中推断出防烟空气幕的计算方法。