The 10th North American Josephson voltage standard (JVS) interlaboratory comparison (ILC) at 10 V was completed in 2014. This year's ILC was unique as it consisted of 2 parts. An on-site comparison was conducted between the National Institute of Standards and Technology (NIST) compact JVS and the pivot laboratory's conventional JVS (CJVS) system. A set of four traveling Zener voltage standards then served to transfer traceability from the pivot laboratory to the 12 other participants. In addition to the regular ILC activities, a second on-site comparison was conducted between the NIST compact JVS and the programmable JVS (PJVS) provided by the National Aeronautics and Space Administration (NASA). Due to limited availability of the PJVS, only two labs were selected to make direct comparison between their CJVS systems and NASA's PJVS. The method has been used for the first time in the JVS ILC and has the advantage of using the PJVS as a transfer standard. This allowed the participating lab to make comparisons using its CJVS system against the 10V PJVS in the same manner as the measurements for Zener standards are performed while overcoming limitations of the Zener noise. We give the results from the 2014 ILC.
机译:10日的第10届北美约瑟夫森电压标准(JVS)在2014年完成10 V的互联网在国家标准和技术研究所(NIST)紧凑型JV和枢轴实验室的传统JV(CJVS)系统之间进行了现场比较。然后,一组四个行驶的齐纳电压标准,然后用于将可追溯性从枢轴实验室转移到其他12名参与者。除常规ILC活动外,在NIST Compact JV和国家航空航天局(NASA)提供的NIST Compact JV和可编程JVS(PJV)之间进行了第二个现场比较。由于PJV的可用性有限,只选择了两个实验室,以便在其CJVS系统和NASA的PJV之间进行直接比较。该方法已在JVS ILC中首次使用,并且具有使用PJV作为传输标准的优点。这允许参与实验室以与10V PJV的CJVS系统以与齐纳标准的测量相同的方式进行比较,同时克服齐纳噪声的限制。我们向2014年ILC提供结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号