Direct JVS Comparison between NIST and SNL to Support NCSLI JVS ILC 2011

机译:NIST和SNL之间的直接JVS比较支持NCSLI JVS ILC 2011

获取原文

摘要

The National Conference of Standard Laboratories International (NCSLI) is scheduled to start its 9th Josephson Voltage Standard (JVS) Interlaboratory Comparison (ILC) in March 2011. Sandia National Laboratories (SNL) is the pivot lab for this comparison of JVS systems that are currently in operation at several U.S. companies and national laboratories. In order to ensure the uniformity and traceability of the representation of the volt based on the Josephson constant 1990 in all the participating labs, the National Institute of Standards and Technology (NIST) DC Volt Lab and SNL performed a direct JVS comparison from December 6, 2010 to December 10, 2010 at the SNL, Albuquerque, NM. In this JVS comparison, the difference between the NIST CJVS and the SNL JVS was found to be -2.08 nV +- 2.88 nV at 10 V (k velence 2). The large number of measurement data points enabled research investigations, such as the evaluation of the impact of the null detector's gain error and the filter network on the comparison result. The team discovered that the polarization of the dielectric material of the SNL cryoprobe filter capacitors could affect the comparison outcome. The difference between the two JVSs was reduced from -6.50 nV to -2.08 nV by extending the waiting period for the capacitor recovery from polarization to equilibrium. An in-situ JVS comparison between the NIST CJVS and the SNL JVS via a set of Zener transfer standards at 10 V was also carried out. The difference was 12 nV +- 21 nV at 10 V (k velence 2). This result is consistent with the results from similar past JVS ILC comparisons. The same set of Zeners will be used in the JVS ILC that is scheduled to begin in March 2011. The result of this direct JVS comparison achieved an uncertainty level comparable to the international key comparison BIPM.EM.K10.b in the Bureau International des Poids et Mesures (BIPM) Key Comparison Data Base (KCDB). This bilateral JVS comparison has confirmed that SNL is capable of performing its role as the pivot lab in the upcoming NCSLI JVS ILC. The results of the NCSLI JVS ILC will allow its participants to establish a voltage measurement link to NIST via the pivot lab SNL.
机译:全国标准实验室国际会议国际(NCSLI)计划于2011年3月开始第9届约瑟夫森电压标准(JVS)互联网(JV)。桑迪亚国家实验室(SNL)是目前的JVS系统比较的Pivot实验室在若干美国公司和国家实验室的行动中。为了确保基于Josephson常数1990在所有参与的实验室中基于Josephson常数的均匀性和可追溯性,美国国家标准和技术研究所(NIST)直流伏格实验室和SNL从12月6日执行了直接的JVS比较, 2010年至2010年12月10日在SNL,Albuquerque,NM。在该JVS比较中,NIST CJV和SNL JV之间的差异被发现为10V(k丝光灯2)的-2.08 nV + - 2.88nv。启用了大量测量数据点,使得研究调查,例如评估空探测器的增益误差和过滤网络对比较结果的影响。该团队发现SNL冷冻探针滤波器电容器的介电材料的偏振可能会影响比较结果。通过将电容器恢复的等待时间扩展到偏振来延长到平衡,从-6.50 nV到-2.08 nV减小了两种JVS之间的差异。还执行了通过一组10V的一组齐纳转移标准的NIST CJV和SNL JV之间的原位JVS比较。差异为10V(k柔性2),差异为12 nV + - 21nV。该结果与类似于过去的JVS ILC比较的结果一致。同一组齐纳将在JVS ILC中使用,计划于2011年3月开始。这种直接JVS比较的结果取得了与国际委员会国际德国国际关键比较BIPM.EM.K10.B相当的不确定性水平poids et mesures(bipm)键比较数据库(KCDB)。这种双边JVS比较已证实,SNL能够在即将到来的NCSLI JVS ILC中执行其作为Pivot实验室的作用。 NCSLI JVS ILC的结果将允许其参与者通过Pivot Lab SNL建立与NIST的电压测量链接。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号