The rapid inspection method of an O-E receiver

机译:O-E接收器的快速检查方法

获取原文

摘要

For the first time, the rapid inspection method of an O-E receiver based on second-harmonic is proposed for measuring 1.064 micrometers and 0.91 micrometers laser pulse with duration of about 10nm. By comparing the two waveforms from a pulse of laser, we achieve more than 0.6% relative error of pulse-width. The opto- electronic receive have inspected come into use for measuring laser waveform. The measurement uncertainties of ratio of integration area to peak voltage of the laser waveform is 0.6%. It is shown that the ratio is an important parameter for evaluating the accuracy of laser waveform, in contrast, the transient time invariance and linearity of opto-electronic detector is verified.
机译:首次,提出了基于二次谐波的O-E接收器的快速检查方法,用于测量1.064微米和0.91微米的激光脉冲,持续时间约为10nm。通过比较来自激光脉冲的两个波形,我们达到脉冲宽度的0.6%以上的相对误差。光电接收已检查以用于测量激光波形。积分面积与激光波形峰值电压的比例的测量不确定性为0.6%。结果表明,该比率是用于评估激光波形的准确性的重要参数,相比之下,验证光电检测器的瞬态时间不矛盾和线性度。