Power measurements can benefit from spectral analysis. It may, however, also lead to errors that are not immediately recognizable, caused by spectral leakage due to imperfect phaselocking in measurement systems. This paper analyses this problem for low-frequency ac power measurements. The conclusion is that if any spectral decomposition is made, care should be taken not to use excessive measurement times, and that the phase-locked loop bandwidth should be kept as low as possible.
机译:功率测量可以从光谱分析中受益。然而,它可能也导致不立即识别的错误,这是由于测量系统中不完美的缺陷引起的光谱泄漏引起的。本文分析了低频交流电源测量的问题。结论是,如果进行了任何光谱分解,则应注意不使用过量的测量时间,并且锁相环带宽应尽可能低。