首页> 外文会议>電気学会全国大会 >Partial Discharge Characteristics of Simulated XLPE/EPR Cable Interface and Degradation Interpretation by Fourier Transfer Infrared Spectroscopy Analysis
【24h】

Partial Discharge Characteristics of Simulated XLPE/EPR Cable Interface and Degradation Interpretation by Fourier Transfer Infrared Spectroscopy Analysis

机译:模拟XLPE / EPR电缆接口的局部放电特性和傅里叶传输红外光谱分析的劣化解释

获取原文

摘要

In order to improve long-term reliability of cross-linked polyethylene (XLPE) power cables, it is essential to understand the mechanisms of degradation and breakdown of XLPE solid insulation and interfacial phenomena. Previous research has performed investigation of partial discharge (PD) characteristics and insulation deterioration by electron spectroscopy for chemical analysis (ESCA). In this paper, we focus on the investigation of degradation mechanism of simulated XLPE/EPR interface by Fourier Transform Infrared (FT-IR) Spectroscopy Analysis in terms of elucidation of the degradation process of XLPE cable joint.
机译:为了提高交联聚乙烯(XLPE)电力电缆的长期可靠性,必须了解XLPE固体绝缘和界面现象的降解和崩溃的机制。以前的研究表明了通过电子光谱学的局部放电(Pd)特性和绝缘劣化进行化学分析(ESCA)。在本文中,我们专注于傅里叶变换红外(FT-IR)光谱分析在XLPE电缆接头的降解过程中傅里叶变换红外(FT-IR)光谱分析对模拟XLPE / EPR接口降解机制的研究。