The paper describes the results of safety and maintenance design studies of 600MWt HTGR-GT power plant based on the results obtained in the feasibility study. (1) At the depressurization accident, passive coolability of HTGR-GT system designed in present study was examined and verified by the safety analysis. (2) FPs (137{sup left}Cs and (110m){sup left}Ag) inventory in th helium gas and radiation exposure to the public at the pipe rupture accident were evaluated and the safety design concept of the system was verified. (3) Disassembly/assembly procedures of turbomachinary of HTGR-GT system were proposed with remote maintenance equipment.
机译:本文介绍了基于可行性研究中获得的结果的600MWT HTGR-GT发电厂的安全性和维护设计研究结果。 (1)在减压事故中,通过安全分析检查和验证了本研究中设计的HTGR-GT系统的被动冷却性。 (2)FPS(137 {SUP左} CS和(110米){SUP左} AG)评估了在管道破裂事故中对公众的氦气和辐射暴露的库存,并验证了系统的安全设计概念。 (3)采用远程维护设备提出了HTGR-GT系统涡轮大学拆卸/装配程序。