This study involves computer simulations of Carolina Power & Light's Cape Fear Unit 6 furnace. The furnace is a tangentially fired twin furnace with a total of 40 burners, each half having 20 burners arranged in four vertical rows. The main fuel is pulverized coal. The boiler has been studied at a net load of 173 MWe, corresponding to a firing rate of 475 MWt. To meet new regulations regarding NO{sub}x, CP & L is reviewing technologies to reduce NO{sub}x emissions. This study relates to the application of MobotecSystem. The MobotecSystem consists of: · ROFA (Rotating Opposed Fire Air) · ROTAMIX (Rotary Mixing of Chemicals) · SCR (Selective Catalytic Reduction) This report is mainly considering the first step in the MobotecSystem, i.e. ROFA. Through a CFD-analysis, the fluid flow for the baseline case (existing configuration) is compared to the corresponding flow introduced by the ROFA technique.
机译:本研究涉及Carolina Power&Light的Cape Fair 2炉的计算机模拟。炉子是一条切向燃烧的双炉,总共40个燃烧器,每半都有20个燃烧器,以四个垂直行排列。主燃料是煤粉。锅炉已经在173 mWE的净负载下进行了研究,对应于475 MWT的烧制率。为了满足关于NO {Sub} X的新规定,CP&L正在审查技术以减少NO {Sub} x排放。本研究涉及MoboteCsystem的应用。 MoboteCsystem包括:·罗法布(旋转对抗火空)·Rotamix(化学品的旋转混合)·SCR(选择性催化还原)本报告主要考虑MoboteCsystem,即Rofa的第一步。通过CFD分析,将基线壳体(现有配置)的流体流与ROFA技术引入的相应流程进行比较。