First experiences with a slitlamp-adapted optical coherence tomography (OCT) system in the anterior and posterior segment of the eye

机译:在眼睛的前段和后部段中的粘液适应光学相干断层扫描(OCT)系统的首先经历

获取原文

摘要

Optical Coherence Tomography (OCT) is a new in vivo imaging device in ophthalmology. We investigated the diagnostic potentials of a slitlamp-adapted OCT in the examination of not only the posterior but also the anterior segment in vivo. Patients were examined with a new prototype of a slitlamp- adapted OCT (Fa.Schwind, D-Kleinostheim) in the anterior and posterior segment using 100 - 200 axial scans with 50 Hz scan frequency. The scan length is variable up to 7.5 mm. The software allows to evaluate the images in gray scale or false color. By the slitlamp-adapted OCT all anatomic structures and morphological changes anterior to the attenuating iris pigment epithelium including the anterior chamber angle can be demonstrated and measured precisely. Within the pupillary opening OCT-imaging of cataract, secondary cataract formation as well as the anterior vitreous can be performed. The slitlamp-adapted OCT also allows direct biomicroscopic control of the measured area in examinations of the posterior segment. The slitlamp-adapted OCT provides a new and helpful diagnostic tool, which allows a precise examination of the anterior and posterior segment of the eye. The advantage of this new method lies in the combination of the familiar examination technique and the simultaneous slitlamp view, which provides an exact position control. It is possible to do pachymetric studies of the cornea after photorefractive and phototherapeutic therapy. Of importance is the objective measurement of the chamber angle, which may improve pre- and postoperative evaluation and allow a better follow up documentation of glaucoma patients.
机译:光学相干断层扫描(OCT)是眼科中的一种新的体内成像装置。我们调查了Slitlamp适应的OCT的诊断潜力,在视线上进行检查,而且还在体内的前段中进行检查。使用具有50 Hz扫描频率的100-200轴扫描,用脊柱液适应的OCT(Fa.schwind,D-Kleinosim)的新原型检查患者。扫描长度可变高达7.5毫米。该软件允许以灰度或假颜色评估图像。通过Slitlamp适应的OCT,所有解剖结构和形态学变化可以精确地证明和测量包括前房角度的衰减虹膜颜料上皮。在白内障的瞳孔开口OCT-成像中,可以进行二次白内障形成以及前玻璃体。 Slitlamp适应的OCT还允许在后部的检查中直接生物学控制测量区域。 Slitlamp适应的OCT提供了一种新的和有用的诊断工具,可以精确地检查眼睛的前段和后段。这种新方法的优点在于熟悉的检查技术的组合和同时索壁灯光灯,其提供精确的位置控制。在光折叠和光照疗法后,可以对角膜进行偶变。重要性是腔室角度的客观测量,可以改善术后评价和更好地进行青光眼患者的文献。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号